Model | PNP output | F3SJ-E[][][][]P25 |
---|---|---|
NPN output | F3SJ-E[][][][]N25 | |
Sensor type | Type 4 safety light curtain | |
Setting tool connection *1 | Parameter settings: Not available | |
Safety category | Safety purpose of category 4, 3, 2, 1, or B | |
Detection capability | Opaque objects 25 mm in diameter | |
Beam gap (P) | 20 mm | |
Number of beams (n) | 8 to 54 | |
Protective height (PH) | 185 to 1,105 mm | |
Lens diameter | Diameter 5 mm | |
Operating range *2 | 0.2 to 7 m | |
Response time (under stable light incident condition) |
ON to OFF | 15 ms max. |
OFF to ON | 70 ms max. | |
Startup waiting time | 2 s max. | |
Power supply voltage (Vs) | SELV/PELV 24 VDC±20% (ripple p-p 10% max.) | |
Consumption current (no load) |
PNP output |
Emitter: Up to 22 beams: 41 mA max., 26 to 42 beams: 57 mA max., 46 to 54 beams: 63 mA max. Receiver: Up to 22 beams: 42 mA max., 26 to 42 beams: 47 mA max., 46 to 54 beams: 51 mA max. |
NPN output |
Emitter: Up to 22 beams: 41 mA max., 26 to 42 beams: 57 mA max., 46 to 54 beams: 63 mA max. Receiver: Up to 22 beams: 40 mA max., 26 to 42 beams: 45 mA max., 46 to 54 beams: 48 mA max. |
|
Light source (emitted wavelength) |
Infrared LED (870 nm) | |
Effective aperture angle (EAA) |
Based on IEC 61496-2. Within ±2.5° for both emitter and receiver when the detection distance is 3 m or over |
|
Safety outputs (OSSD) |
PNP output |
Two PNP transistor outputs, load current 200 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension), Leakage current 1 mA max., load inductance 2.2 H max. *3, Maximum capacity load 1 μF *4 |
NPN output |
Two NPN transistor outputs, load current 200 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension), Leakage current 1 mA max., load inductance 2.2 H max. *3, Maximum capacity load 1 μF *4 |
|
Output operation mode | Safety output: On when receiving light | |
Input voltage | PNP output | ON voltage: Vs-3 V to Vs, OFF voltage: 0 V to 1/2 Vs or open *5 |
NPN output | ON voltage: 0 V to 3 V OFF, voltage: 1/2 Vs to Vs or open *5 | |
Mutual interference prevention function |
Mutual interference prevention algorithm prevents interference in up to 3 sets. | |
Test function |
Self test (at power-ON and at power distribution) External test (emission stop function by test input) |
|
Protection circuit | Output short-circuit protection, and power supply reverse polarity protection | |
Ambient temperature | Operating: -10 to 55°C (non-freezing), Storage: -25 to 70°C | |
Ambient humidity | Operating: 35% to 85% (no condensation), Storage: 35% to 95% RH | |
Operating ambient light intensity |
Incandescent lamp: 3,000 lx max., Sunlight: 10,000 lx max. | |
Insulation resistance | 20 MΩ min. (at 500 VDC) | |
Dielectric strength | 1,000 VAC 50/60 Hz, 1 min | |
Degree of protection | IP65 (IEC 60529) | |
Vibration resistance |
Malfunction: 10 to 55 Hz, Multiple amplitude of 0.7 mm, 20 sweeps in X, Y, and Z directions |
|
Shock resistance | Malfunction: 100 m/s2, 1,000 times each in X, Y, and Z directions | |
Pollution degree | Pollution degree 3 (IEC 60664-1) | |
Power cable |
Connection method: Pull-out type, cable length 3 m Number of wires: Emitter: 5 wires, receiver: 6 wires Cable diameter: Dia. 6 mm Allowable bending radius: R5 mm |
|
Extension cable | 30 m max. *6 | |
Material |
Case: Aluminum Cap: ABS resin, PBT Optical cover: PMMA resin (acrylic) Cable: Oil resistant PVC |
|
Weight (packed state) | Weight (g) = (protective height) x 2.6 + 800 | |
Accessories | Test rod, Instruction Manual, User's Manual (CD-ROM) *7 | |
Applicable standards |
IEC 61496-1, EN 61496-1, UL 61496-1, Type 4 ESPE (Electro-Sensitive Protective Equipment) IEC 61496-2, CLC/TS 61496-2, UL 61496-2, Type 4 AOPD (Active Opto-electronic Protective Devices) IEC 61508-1 to -3, EN 61508-1 to -3 SIL3 ISO 13849-1: 2006, EN ISO 13849-1: 2008 (PLe/Safety Category 4) UL 508, UL 1998, CAN/CSA C22.2 No.14, CAN/CSA C22.2 No.0.8 |
*1. Do not use the Support Software and Setting Console for F3SJ-A. Operation cannot be guaranteed.
*2. Use of the Spatter Protection Cover causes a 10% maximum sensing distance attenuation.
*3. The load inductance is the maximum value when the safety output frequently repeats ON and OFF. When you use the
safety output at 4 Hz or less, the usable load inductance becomes larger.
*4. These values must be taken into consideration when connecting elements including a capacitive load such as
capacitor.
*5. The Vs indicates a voltage value in your environment.
*6. To extend a cable of the F3SJ-E, refer to the User's Manual (SCHG-733/732).
*7. Mounting brackets are sold separately.
*2. Use of the Spatter Protection Cover causes a 10% maximum sensing distance attenuation.
*3. The load inductance is the maximum value when the safety output frequently repeats ON and OFF. When you use the
safety output at 4 Hz or less, the usable load inductance becomes larger.
*4. These values must be taken into consideration when connecting elements including a capacitive load such as
capacitor.
*5. The Vs indicates a voltage value in your environment.
*6. To extend a cable of the F3SJ-E, refer to the User's Manual (SCHG-733/732).
*7. Mounting brackets are sold separately.